Cryogenic readout for multiple VUV4 Multi-Pixel Photon Counters in liquid xenon

23 Sept 2017, 09:00
15m
Kavli Auditorium (SLAC National Accelerator Laboratory)

Kavli Auditorium

SLAC National Accelerator Laboratory

Menlo Park, CA 94025
Presentation Light/charge readout (PMTs, SiPM, WLS, electronics, etc.) Saturday Morning 1

Speaker

Dr Adriano Di Giovanni (NYUAD)

Description

We present the performances and characterization of an array made of S13370-3050CN (VUV4 generation) Multi-Pixel Photon Counters manufactured by Hamamatsu and equipped with a low power consumption preamplifier for operations in liquid xenon environment. The electronics is designed for the readout of a 8×8 matrix of individual photosensors and it is based on a single operational amplifier (Analog Devices AD8011). A biasing correction circuit has been implemented for the gain equalization of photosensors operating at different voltages. We present the results of the characterization which show a distinct single photon detection capability that makes this device a promising choice for future generation of large scale dark matter detectors based on liquid xenon.

Primary authors

Dr Adriano Di Giovanni (NYUAD) Prof. Francesco Arneodo (NYUAD) Dr Giovanni Franchi (age scientific srl) Prof. Mohamed Lotfi Benabderrahmane (NYUAD)